  • 无菌室装修设计规范化要求是什么?
    来源:最新澳门网址大全 浏览: 发布日期:2020-07-11
    无菌室也称接种室,是系统接种、纯化菌种等无菌操作的专用实验室。在微生物工作中,菌种的接种移植是一项主要操作,这项操作的特点就是要保证菌种纯种,防止杂菌的污染。在一般环境的空气中,由于存在许多尘埃和杂菌,很易造成污染,对接种工作干扰很大。小析姐为您介绍下微生物无菌室装修设计规范化。
    Aseptic room, also known as inoculation room, is a special laboratory for aseptic operation such as systematic inoculation and purification of bacteria. In the microbial work, the inoculation and transplantation of bacteria is a major operation. The characteristics of this operation are to ensure the purity of strains and prevent the contamination of miscellaneous bacteria. In the air of general environment, because of the existence of many dust and miscellaneous bacteria, it is easy to cause pollution, which greatly interferes with the vaccination work. Xiaojie introduces the standardization of decoration design of microbial aseptic room for you.
    无菌室应根据既经济又科学的原则来设置。其基本要求有以下几点:
    Aseptic room should be set up according to the principle of economy and science. The basic requirements are as follows:
    (1)无菌室应有内、外两间,内间是无菌室,外间是缓冲室。房间容积不宜过大,以便于空气灭菌。内间面积2×2.5=5m2,外间面积1×2=2m2,高以2.5m以下为宜,都应有天花板。
    (1) The aseptic room should have internal and external rooms. The inner room is the sterile room and the outer room is the buffer room. Room volume should not be too large to facilitate air sterilization. The inner area is 2 × 2.5 = 5m2, and the outer area is 1 × 2 = 2M2. The height should be less than 2.5m, and there should be ceiling.
    (2)内间应当设拉门,以减少空气的波动,门应设在离工作台更远的位置上;外间的门更好也用拉门,要设在距内间更远的位置上。
    (2) Sliding door should be set in the inner room to reduce the air fluctuation. The door should be set at the farthest position from the working table; the door of the outer room should also use the sliding door, which should be set at the farthest position from the inner room.

    (3)在分隔内间与外间的墙壁或“隔扇”上,应开一个小窗,作接种过程中必要的内外传递物品的通道,以减少人员进出内间的次数,降低污染程度。小窗宽60cm、高40cm、厚30cm,内外都挂对拉的窗扇。
    (3) A small window should be opened on the wall or "partition" separating the internal and external rooms, which is necessary for the internal and external transmission of articles during the inoculation process, so as to reduce the number of people entering and leaving the inner room and reduce the pollution degree. The window is 60cm in width, 40cm in height and 30cm in thickness.
    (4)无菌室容积小而严密,使用一段时间后,室内温度很高,故应设置通气窗。通气窗应设在内室进门处的顶棚上(即离工作台更远的位置),更好为双层结构,外层为百叶窗,内层可用抽板式窗扇。通气窗可在内室使用后、灭菌前开启,以流通空气。有条件可安装恒温恒湿机。
    (4) The volume of aseptic room is small and tight. After using for a period of time, the indoor temperature is very high, so ventilation window should be set. The ventilation window should be set on the ceiling at the entrance of the inner room (i.e. the farthest position from the working table). It is better to have a double-layer structure. The outer layer is made of louvers, and the inner layer can be made of draw plate window fans. The ventilation window can be opened after the inner chamber is used and before sterilization to circulate air. If possible, constant temperature and humidity machine can be installed.
    以上就会说无菌室装修为大家介绍装修设计几点基本要点,更多的详情内容请关注我们官网:
    The above will say that aseptic room decoration introduces some basic points of decoration design for you. For more details, please pay attention to our official website: